part.alarm
(re fer to “Stop Par ti tion Alarms”),
Print log ger
(NOT ava i la ble!). Press
ON
or
OFF
, re spec ti vely, to ena -
ble or di sa ble the fun ction con cer ned (“
û
” me ans ena bled,
and “
-
” me ans di sa bled). Press
ENTER
to go to step 3.
Op
tio
n section 5
Arming type A x
9.
Using
A
or
B
, se lect the fun ctions from Option sec -
tion 5:
Arming type A
(re fer to “Arming A with user
code”),
Arming type B
(re fer to “Arming B with user
code”),
Arming type C
(re fer to “Arming C with user
code”),
Arming type D
(re fer to “Arming D with user
code”),
Away ar ming
(re fer to “Away ar ming with user
code”),
Di sar ming
(re
fer to “Di
sar ming with user
code”). Press
ON
or
OFF
, re spec ti vely, to ena ble or di -
sa ble the fun ction con cer ned (“
û
” me ans ena bled, and
“
-
” me ans di sa bled). Press
ENTER
to go to step 3.
n
Instal ler Code Types
Op
tio
n block 1
Even
t logger x
5a.
Using
A
or
B
, se lect the fun ctions from Option sec -
tion 1:
Event log ger
(re fer to “View log ger”),
Zone sta -
tus
(re fer to “Zone Sta tus”),
Zone test
(re fer to “Zone
Test”),
Out puts test
(re fer to “Out put Test”),
Cle ar call
que ue
(re fer to “Cle ar Call Qu e ue”),
Vo i ce fun ctions
(re fer to “Vo
i ce Fun
ctions”),
Instal ler PIN
(re
fer to
“Chan ge Instal ler PIN”),
User co des
(re fer to “User Co -
des”). Press
ON
or
OFF
, re spec ti vely, to ena ble or di sa -
ble the fun ction con cer ned (“
û
” me ans ena bled, and “
-
”
me ans di sa bled). Press
ENTER
to go to the next Option
sec tion.
Option block 2
Di
gi
tal Keys x
6a.
Using
A
or
B
, se lect the fun ctions from Option sec tion 2:
Di gi tal keys
(re fer to “Di gi tal Keys”),
Pro gram Pa nel
(re fer
to “Pa nel pro gram ming”),
Enrol wi re less
(re fer to “Enrol
Wi re less”),
Upda te strings
(re fer to “Key pad Bro ad cast”),
Chan ge time/date
(re fer to “Chan ge date/time”). Press
ON
or
OFF
, re spec ti vely, to ena ble or di sa ble the fun ction
con cer ned (“
û
” me ans ena bled, and “
-
” me ans di sa bled).
Press
ENTER
to go back to step 3.
N
EVENT
0000 + n
Alarm on zone no.
0280 + n
Alarm on zone no. – Wireless
0344 + n
Tamper on zone no.
0624 + n
Tamper on zone no. – Wireless
Ta bel la 1
Zo nes events for KYO320
N
EVENT
0688 + n
Fire alarm on partition no.
0720 + n
24h alarm on partition no.
0752 + n
Burglar alarm on partition no.
0784 + n
Generic alarm on partition no.
0816 + n
Tamper alarm on partition no.
0848 + n
Tamper alarm on partition n.
0880 + n
Away alarm on partition no.
0912 + n
Stay alarm on partition no.
Ta bel la 2
Par ti tion events for KYO320
N.
EVENTI
0945
Fire alarm on panel
0946
24h alarm on panel
0947
Burglar alarm on panel
0948
Generic alarm on panel
0949
Tamper alarm on panel
0950
Tamper alarm on panel
0951
Tamper on Main unit
0952
Stop-alarms jumper
0953
Balanced tamper
0953 + n
Tamper on supervised output no.
0957
Tamper BPI readers
0958
Tamper BPI input expanders
0959
Tamper keypads
0960
Tamper LED Keypad
0961
Tamper output expanders
0962
Tamper power stations
0963
Tamper wireless device
Ta bel la 3
KYO 320 Pa nel events
N.
EVENTI
0964
Warning readers
0965
Warning BPI input expander
0966
Warning keypad
0967
Warning LED keypad
0968
Warning output expanders
0969
Warning power stations
0970
Warning wireless device
0971
False key
0972
Warning fuse +F
0973
Warning fuse +B1
0974
Warning fuse +B2
0975
Warning fuse +B3
0976
Warning fuse +B4
0977
Warning fuse +B5
0978
Warning fuse BPI1
0979
Warning fuse BPI2
0980
Warning fuse KEYBUS
0981
Warning mains failure
0982
Warning low battery
0983
Warning power trouble