Programming Alarm zones
Work ca re fully thro ugh the fol lo wing steps.
Zone Type
Instan
t x
7a.
Using
A
or
B
, se lect the
Zone type
(
Instant
,
Entry
de lay
,
Entry path
,
Exit de lay
,
Last exit
,
24 ho urs
,
Fire
or
Du ress
). The zone types that will be ava i la ble
de pend on the zone set tings.
Using
ON
or
OFF
, ena ble/di sa ble the se lec ted
zone
type (“
û
” me
ans ena
bled, and “
-
” di
sa bled), press
ENTER
to go to the next step.
Zone Attri
bu
te
Unbypas
sable -
7b.
Using
A
or
B
, se lect the zone at tri bu te (
Unbypas -
sa ble
,
Chi me
,
Test
,
Au tob ypas sa ble
,
Au tobyp.+re -
inc.
(re fer to “Au tob ypass with re set unbypass”),
Stay
,
De lay on part.
(re
fer to “De
la yed on stay ar
ming”),
Del&Est. r.t.a.
(re fer to “De la yed and esti ma ted on re -
ady to arm”), Disp.Entry Time (re fer to “Di splay du ring
Entry Time”). The at tri bu tes that will be ava i la ble de -
pend on the zone set tings.
Using ON or OFF, ena ble/di sa ble the se lec ted
zone
at -
tri bu te “
û
” me
ans ena
bled, and “
-
” di
sa bled), then
press
ENTER
to go to the next step.
8b.
Using
A
or
B
se lect, in this sec tion, the zone at tri bu -
tes “
Vi bra tion
” and “
Rol ler Blind
” (for the first eight zo -
nes ONLY)
Zone Attri
bu
te
Roller Blind
Using
ON
or
OFF
, ena ble/di sa ble the se lec ted
zone
at -
tri bu te “
Vi bra tion
” and “
Rol ler Blind
” , “
û
” me ans ena -
bled, and “
-
” di sa bled). Re fer to fol lo wing Ta ble for
ot her pa
ra me ters re
le vant to Zo
nes with the ‘
Rol ler
Blind
’
at tri bu te.
Times/
Pulses
1
2
3
4
5
6
7
30 s
0
1
2
3
4
5
6
2 min.
7
8
9
10
11
12
13
4 min.
14
15
16
17
18
19
20
Always
21
22
23
24
25
26
27
Exam ple: for 3 PULSES and 4 MINUTES, you must set
a va lue of 16.
To set the two at tri bu tes of a “
Vi bra tion
” zone
Vibration
Sen
si
tivityà 00
Set the sen si ti vity va lue from 0 up to 30, and the Pul se
va lue from 1 up to 7.
Vibration
Pulses 0
9.
press
ENTER
.
Cycles
Repetitive
7c.
Enter the re qui red num ber of cycles, or en ter all ze -
ros to set Re pe ti ti ve, then press
ENTER
and go to step
8c
.
8c.
This pa ra me ter de ter mi nes the num ber of ti mes the
zone will ge ne ra te the
Alarm on zone
event.
Va lid en tries:
Cycles
from
1
to
254
or
Re pe ti ti ve
.
If the zone is a
Glass Bre ak
zone, the
Cycles
pa ra me -
ter will be for ced to
1
.
n
Pro gram ming Com mand zones
If you se
lec ted
Com
mand
at
step 6
, work ca
re fully
thro ugh the fol lo wing steps.
Select command
Toggle arm/dis x
7d.
Using
A
or
B
, se lect the
Action/s
that will be ge ne -
ra ted by the Com mand zone (
Tog gle arm/dis.
(re fer to
“Arm/Di sarm/Tog gle”),
Hard arm/dis.
(re fer to “Arm/Di -
sarm hard”),
Arm only
,
Di sarm only
,
Par ti tion re set
,
Pa nel re set
,
Del.tel.que ue
(re fer to “Cle ar call que ue”).
8.
Using
ON
or
OFF
, ena
ble/di sa ble the se
lec ted
Action/s (“
û
” me ans ena bled, and “
-
” di sa bled), then
press
ENTER
.
The
Alarm Mes sa ges
sec tion is for
Alarm
and
Com -
mand
zo nes.
Alarm mes.n. ---
None
This pro gram ming sec tion will al low you to as sign two
vo i ce mes sa ges (from the 64 ava i la ble) to the zone con -
cer ned. You can as sign one mes sa ge to
Standby
sta -
tus and the ot her to
Alarm
sta tus.
If you se lect “
None
”
in the
Alarm Mes sa ge
field, Alarm
sta tus will be si gnal led by two Be eps, when the system
is ac ces sed over the pho ne.
If you se lect “
None
” in the
Standby Mes sa ge
field,
Standby sta tus will be si gnal led by one Beep, when the
system is ac ces sed over the pho ne.
9.
Using
A
or
B
, se lect the mes sa ge num ber or “
None
”,
then press
ENTER
.
Stdby mes.n. ---
None
For the Standby mes sa ge, re pe at step 9, then press
ENTER
.
10.
The
Par ti tions
pa ra me ter as su mes dif fe rent me a -
nings for
Alarm
zo nes and
Com mand
zo nes.
Par
ti
tion 1-8
x
22