Armed Mess.n ---
None
15.
Using
A
or
B
, se lect the Vo i ce mes sa ge (or None),
as si gned to Par ti tion Armed sta tus, then press
ENTER
:
Disar.mess n.---
None
16.
Using
A
or
B,
se lect the Vo i ce mes sa ge (or None),
as si gned to Par
ti tion Di
sar med sta
tus, then press
ENTER
:
Partition Co
de
Co
de 000000
17.
Enter the Par ti tion code, then press
ENTER
to go
back to step 3.
If the
Send al ways
op tion is di sa bled (re fer to “
Di gi tal
Com mu ni ca tor
” sec
tion), the Di
gi tal Com
mu ni ca tor
will send the
Par ti tion code
and the Event Code to the
Cen tral Sta tion/s when a par ti tion re la ted event oc curs
(as so cia ted with the Di gi tal Com mu ni ca tor).
+
The Par ti tion Code must have 6 di gits.
Keys/Card
From the “PROGRAMMING” menu.
PROGRAMMING
Configuration
1.
Using
A
or
B
, se lect the
Keys
op tion.
PROGRAMMING
Keys /Card
2.
Press
ENTER
:
Keys /Card
Digital Key
3.
Using
A
or
B
, se lect eit her
Di gi tal key
or
Wi re less
key
as re qui red, then press
ENTER
.
Dig. Key n. 001
Digital key 001
4.
Using
A
or
B
, se lect the re qui red di gi tal key, then
press
ENTER
.
De
scri
ption
Di
gi
tal key 001
5.
Enter the di gi tal key la bel (re fer to “Edi ting a text” un -
der “Using the Key pad”), then press
ENTER
.
Digitalkey 001
Enabled _
6.
Using
ON
or
OFF
, re spec ti vely, ena ble or di sa ble the
di gi tal key con cer ned, then using
A
or
B
, se lect the
Pa -
trol
at tri bu te.
Di
gi
tal Key 001
Patrol
7.
Using
ON
or
OFF
, re spec ti vely, ena ble or di sa ble the
Pa trol
at tri bu te for the di gi tal key con cer ned, then using
C
or
D
,
se lect the
Stop Par ti tion Alarms
.
Di
gi
tal key 001
Stop part.alarmx
7a.
Using
ON
or
OFF
, re spec ti vely, ena ble or di sa ble
the
Stop Par ti tion Alarms
for the di gi tal key con cer ned
(re fer to “Stop Par ti tion Alarms”) then, using
C
or
D
se -
lect the
Del.tel.que ue
at tri bu te.
Di
gi
tal key 001
Del.tel.que
ue -
8.
Using
ON
or
OFF
, re spec ti vely, ena ble or di sa ble
the
Del.tel.que ue
at
tri bu te for the di
gi tal key con
cer ned
(re fer to“De le te Call que ue on Di sar ming”), then using
C
or
D
, se lect
Stop pa nel alar.
Di
gi
tal key 001
Stop pa
nel alarm
9.
Using
ON
or
OFF
, re spec ti vely, ena ble or di sa ble
the
Stop pa
nel Alarms
at tri bu te (re
fer to “Stop Pa
nel
Alarms”), then press
ENTER
.
Max Nu
m. access
Always
10.
Enter the num ber of ti mes the di gi tal key will be al lo -
wed to ac cess the system, then press
ENTER
. To al low
un li mi ted use, en ter zero (0).
Ass.Ti
mer n. ---
None
11.
Using
A
or
B
, se lect the
Ti mer
which will con trol the
di gi tal key (the bot tom line will show the la bel of the se -
lec ted Ti mer), then press
ENTER
.
Partition 1-8
XXXXXXXX
12.
Ena ble the Key on the re le vant Par ti tions (re fer to
“Ena bling Par ti tions and A, B, C and D Mode” un der
“Using the Key pad”), then press
ENTER
.
To pro gram the wi re less keys, go back to step 3, then
using
A
or
B
, se lect the
Wi re less keys
op tion.
Key /Card
Wi
re
less Key
4a.
Press
ENTER
:
KYO320
PROGRAM PANEL
27