To unen rol an Out put Expan der
2
(de le te from the Con fi -
gu ra tion), press
OFF
.
5.
Press
ESC
to go back to the Con fi gu ra tion menu.
n
Po wer Sta tion
This Con trol pa nel is una ble to sup port Po wer sta tions.
The fol lo wing in struc tions are for up gra ded mo dels only.
From the Con fi gu ra tion menu, using
A
or
B
, se lect the
Po wer sta tions
op tion:
Con
fi
gu
ra
tion
Power stations
1.
Press
ENTER
Power stat. 001
PowerStation 001
2.
Using
A
or
B
, se lect the Po wer Supply Sta tion to be
pro gram med then press
ENTER
.
De
scri
ption
PowerStation 001
3.
Enter the Po wer Supply Sta tion la bel (re fer to “Edi ting
a text” un der “Using the Key pad”), then press
ENTER
.
PowerStation 001
Not present
4.
Press ON to en rol the Po wer Sta tion (Pre sent), then
press
ENTER
to con ti nue. To unen rol the Po wer Sta -
tion (de le te from the Con fi gu ra tion), press
OFF
.
5.
Enter the
Ma ins Fa ult Ti me o ut
, that is, the amo unt
of time (in se conds) that must ex pi re be fo re the system
ge ne ra tes the
Ma ins Fa i lu re on Po wer Sta tion
event
(re fer to the INSTALLATION MANUAL), then press
ENTER
.
Main Fa
ult Delay
Sec. 0180
6. Enter the Low bat tery de lay, that is, the amo unt of
time (in se conds) that must ex pi re (af ter a re a ding be -
low 11.4 V) be fo re the system ge ne ra tes the Low Bat -
tery on Po
wer Sta
tion event (re
fer to the
INSTALLATION MANUAL).
Batt.Low Delay
Sec. 0180
7.
Press
ENTER
to con ti nue the Po wer Sta tion en rol ling
pha se, or
ESC
to go back to the Con fi gu ra tion menu.
n
Wireless Module
This Con trol pa nel can sup port a Wi re less Re ce i ver.
From the Con fi gu ra tion menu, using
A
or
B
, se lect the
Wi re less mo du le
op tion.
Con
fi
gu
ra
tion
Vector-RX module
1.
Press
ENTER
:
Vector-RX module
Not present
2.
Press
ON
to en rol the Re ce i ver (Pre sent), then press
ENTER
to con ti nue. To unen rol the Re ce i ver (de le te
from the Con fi gu ra tion), press
OFF
.
Su
pervision time
hh.mm 02.30
3.
Enter the
Su per vi sion time
, then press
ENTER
.
Each en rol led wi re less de vi ce will send a su per vi sory
si gnal to the Re ce i ver at re gu lar in ter vals. If the Re ce i -
ver does not re ce i ve the si gnal wit hin the time pro gram -
med in the Su
per vi sion win
dow, it will ge
ne ra te a
su per vi sory fa ult (
Lost wi re less zone
).
+
NOTE:
You must en ter two di gits for the ho urs and
2 for the mi nu tes, (e.g. To pro gram 3 ho urs and 30
mi nu tes, en ter 0330).
Zone contr. time
hh.mm 00.15
4.
Set this op tion for the Su per vi sed Wi re less Zo nes
ONLY(re fer to “Su per vi sed” un der “Wi re less” ). When
the
Zone con trol time
is elap sed from when the Re ce -
i ver has re ce i ved the si gnal that each wi re less zone
sho uld send, the con trol pa nel does not al low the ar -
ming if the "
Di sa ble ar ming on wi re less zo nes fa ult
"
op tion is ena ble (See Option, page 75). Va lid en tries:
15 mi nu tes (at de fa ult) to 2 ho urs (in 15-mi nu te steps).
Options
Jam disable X
5.
Using
ON
or
OFF
, re spec ti vely, ena ble or di sa ble the
RF Jam ming de tec tion op tion, then press
ENTER
.
n
Vox board
This Con trol pa nel can ma na ge the
K3/VOX2
Vo i ce bo -
ard. It is not ne ces sary to en rol the Vox bo ard ma nually,
as this will be done au to ma ti cally by the Con trol pa nel.
Ho we ver, it may be co me ne ces sary to unen rol the Vox
bo ard (e.g. To cle ar Tro u ble si gnal ling), in such ca ses,
using
A
or
B
, se lect the
Vox bo ard
op tion.
Con
fi
gu
ra
tion
Vox Bo
ard
1.
Press
ENTER
:
Vox Board
Not present
2.
Press
OFF
, then press
ENTER
.
20