Error Codes
9-14
Installation, SPM, Maintenance, and Troubleshooting Supplement
8411
E911
NO
OUTGOING
SEIZURE
The system has tried to seize
a trunk assigned either to
E911 Partition or E911
Adjunct for a 911 call and
cannot seize the trunk. The
trunks assigned to the E911
Partition or to the E911
Adjunct go into a Trunk
Maintenance Busy (TMB)
state.
➤
NOTE
An E911 Partition trunk in
a Trunk Maintenance
Busy state can still be
used to make and receive
non-E911 calls.
For an E911 Partitions trunk, any
one of the following can occur:
■
The trunk may automatically
clear if the line is seized for
an outgoing call.
■
Manually seize the trunk by
dialing
*03
and dialing some
digits.
■
The trunk may automatically
clear if the line is used for an
incoming call.
■
The error message is
dropped, and the trunk
clears.
For an E911 Adjunct trunk, do the
following:
■
Check the connections on
the E911 adjunct. If the
situation is corrected, the
TMB state ends during the
system’s TMB recovery.
■
Manually drop the error
message.
■
Manually seize the trunk by
dialing
*03
.
If you manually seize the E911
Adjunct trunk, the adjunct may
place a call to the E911 Service.
Table 9-2. Error Code Descriptions—Continued
Error
Code
Description
Action
Summary of Contents for Lucent Technologies MERLIN MAGIX
Page 2: ......
Page 6: ......
Page 12: ......
Page 24: ...PCMCIA Translation Card 1 12 Installation SPM Maintenance and Troubleshooting Supplement ...
Page 162: ...Installing the E911 Adjunct 6 8 Installation SPM Maintenance and Troubleshooting Supplement ...
Page 178: ...PCMCIA Upgrade Card 7 16 Installation SPM Maintenance and Troubleshooting Supplement ...
Page 266: ...Flow Control 8 88 Installation SPM Maintenance and Troubleshooting Supplement ...