Installing the E911 Adjunct
6-7
Enhanced 911 Service
7.
Connect a tip/ring cable from the E911 adjunct alarm relay to a tip/ring
extension port on a module in the control unit.
8.
Change the E911 Option to “E911 Adjunct.”
9.
Enable “Allow-11” as desired.
10. Remove 911 from any of the programmable ARS tables.
11. Create an Allowed List with 911 and assign it to Outward Restricted and
Extension Status Restricted extensions that should be allowed to call the
911 Emergency Service.
12. Program an operator Alarm button on any operator Direct-Line Consoles
(DLCs).
Do not enable the E911 Adjunct option until after the E911 adjunct
has been connected and tested, the Adjunct Alarm port has been
connected, and the E911 Adjunct trunks and the E911 Adjunct
Alarm have been programmed.