5 0
THIS IS AN UNCONTROLLED DOCUMENT.
THIS ELECTRONIC DOCUMENT MAY HAVE BEEN SUPERCEDED.
THE MOST CURRENT DOCUMENT INFORMATION IS AVAILABLE
FROM YOUR BELL HELICOPTER TEXTRON REPRESENTATIVE.
PRODUCT DATA
JANUARY 2003
The VERTICAL SCALE displays are color coded to show operating parameters, with
green being used to show normal/continuous operating range, yellow for cautionary,
and red for limit/exceeding limit . All fuel information is displayed blue, except for the
last 90 ± 10 pounds (lbs) of fuel which will be displayed red. The DIGITAL information
displays are also color coded; White digits with no background are used to show
normal conditions and values (except NG and AMP where green digits are used), yellow
digits with no background or black digits with a yellow background are used to
show cautionary conditions, and white digits on a red background are used to announce
a warning.
All engine, transmission, hydraulic [temperatures and pressures], and electrical
indications are displayed on the IIDS along with warning, caution, and advisory
messages. Also included is engine and mast torque (Q/MQ), power turbine and
main rotor speed (NP/NR), gas producer speed (NG), and measured gas temperature
(MGT). The electrical systems information shown is voltage and amperage for both
generators, battery voltage, and inverter voltage. Fuel system data displayed is fuel
quantity for both main tanks and total fuel, aux fuel tanks quantity (if installed), and
position of the interconnect valve.
VERTICAL SCALE
PARAMETER DISPLAYS
ALPHANUMERIC
PARAMETER DISPLAYS
EXAMPLE INDICATIONS ON PRIMARY DISPLAY PAGE
FUNCTION KEYS & BRIGHTNESS
COLOR CODED GRAPHIC & DIGITAL DATA
Summary of Contents for BELL 430
Page 1: ...Product Data ...