HCP-1801 HD/SD SDI Control Probe
Guide to Installation and Operation
Page 26 of 27
HCP-1801
•
If the Overall alarm contribution is selected as any level other than disabled, the GSM contribution is forced to follow the
Overall Alarm.
Levels associated with these alarms:
The pulldown lists may contain some or all of the following options:
The alarm makes no contribution (black icon)
The alarm is of minor importance (yellow icon)
The alarm is of major importance (orange icon)
The alarm is of critical importance (red icon)
The alarm exists but has no effect (used for text and composite alarms)
Shortcut: if you click in one of the Set All boxes beside a section heading, you will open a pulldown that lets
you assign a level to all alarms in that section of the column simultaneously.
Log Events
iControl maintains a log of alarm events associated with the card. The log is useful for troubleshooting and identifying event
sequences. Click in the checkbox to enable logging of alarm events for each individual alarm.
At the bottom of the window are several other controls
Copy to other cards
Click this button to open a panel that allows the alarm
configuration set for this card to be copied into another HCP-
1801 card.
•
Select one or more destination cards from the list in
the window by clicking in the checkboxes, or all of
them by clicking in the
All
checkbox
•
Note that when you do a Copy Profile for this card (see
Page 8), the alarm configuration is copied along with
all the other settings.
Get alarm keys
Click this button to open a save dialog where you can save a
file containing a list of all alarms on this card and their current
values, along with an Alarm Key for each. The alarm keys are
useful for system integration and troubleshooting.
•
The file is saved in Excel.csv format
OK, Apply, Cancel
•
OK
accepts the settings and closes the window once
the card confirms that there are no errors.
•
Apply
accepts the settings, but leaves the window
open
•
Cancel
closes the window without applying any
changes, and leaves the previous settings intact.