Installation MACH1000
Release 07 08/2022
47
2.5
Operating the device
When you connect the supply voltage, you start up the device.
2.6
Connecting data cables
You can connect end devices and other segments to the device ports using
twisted pair cables or optical fibers (F/O).
Note the following general recommendations for data cable connections in
environments with high electrical interference levels:
Keep the length of the data cables as short as possible.
Use optical data cables for the data transmission between the buildings.
When using copper cables, provide a sufficient separation between the
power supply cables and the data cables. Ideally, install the cables in
separate cable channels.
Verify that power supply cables and data cables do not run parallel over
longer distances. To reduce inductive coupling, verify that the power
supply cables and data cables cross at a 90 ° angle.
Use shielded data cables for gigabit transmission via copper cables, for
example SF/UTP cables according to ISO/IEC 11801. To meet
EN 50121-4 and marine application requirements, use shielded data
cables at all transmission rates.
Connect the data cables according to your requirements.
See “Ethernet ports” on page 28.
2.6.1
Twisted Pair ports
Connect the data cables according to your requirements.
See “10/100/1000 Mbit/s twisted pair port” on page 29.
See “10/100 Mbit/s twisted pair port” on page 29.
2.6.2
Optical fiber ports
Verify that you connect LH ports only with LH ports, SX ports only with SX
ports, and LX ports only with LX ports.
Connect the data cables according to your requirements.
See “1000 Mbit/s F/O port” on page 30.
See “100 Mbit/s F/O port” on page 30.
See “10 Mbit/s F/O port” on page 30.