34
Installation MACH1000
Release 07 08/2022
Applies to software release 06.0.00 and higher:
If the manual setting is active on the signal contact, then the error display is
independent of the setting of the signal contact.
1.5.2
Port status
The green and yellow LEDs at the individual port display port-related
information. During the boot phase, these LEDs are used to display the
status of the boot procedure.
1.6
Management interfaces
1.6.1
V.24 interface (external management)
The V.24 interface is an RJ11 socket.
The V.24 user interface is serial and allows you to connect the following
devices directly:
External management station (VT100 terminal or PC with appropriate
terminal emulation). With this management station, the Command Line
Interface (CLI) is available to you. Furthermore, the system monitor is
available to you at the system start.
R2
Signal contact 2 yellow lights up
The signal contact is closed in manual operation.
none
The signal contact is open in manual operation.
LED
Display
Color
Activity
Meaning
R1
Signal contact 1 yellow lights up
The signal contact is open.
none
The signal contact is closed.
R2
Signal contact 2 yellow lights up
The signal contact is open.
none
The signal contact is closed.
LS - Data, Link Status (1 green/yellow LED or 1 green and 1 yellow LED)
Not glowing
No valid connection.
Glowing green
Valid connection.
Flashing green (1 × a period)
Port is switched to stand-by.
Flashing green (3 × a period)
Port is disabled.
Flashing yellow
Data reception.
VT100 terminal settings
Speed
9600 Baud
Data
8 bit
Stopbit
1 bit
LED
Display
Color
Activity
Meaning
Summary of Contents for Hirschmann MACH1000 Series