32
Installation MACH1000
Release 07 08/2022
1.5
Display elements
After the supply voltage is set up, the software starts and initializes itself.
Afterwards, the device performs a self-test. During this process, various
LEDs light up. The process takes around 60 seconds.
Figure 8: Display elements MACH1000, device variants with ports in front
1- Display elements device status
2 - Display elements port status
Figure 9: Display elements MACH1000, device variants with ports at the back
1 - Display elements device status
2 - Display elements port status for up to 4 × Gigabit Ethernet ports and
up to 20 × Fast Ethernet ports
3 - Diagnostic port with display element
1.5.1
Device status
These LEDs provide information about conditions which affect the operation
of the whole device.
The following table applies only to device variants with 2 power supply units:
LED Display
Color
Activity
Meaning
P
Supply
voltage
none
Supply voltages 1
and
2 are too low.
green
lights up
Supply voltage 1
and
2 is on
yellow lights up
Supply voltage 1
or
2 is on
USB
V.24
MACH 1000
P
StandBy
RM
FAULT
R1 R2
1
2
P
StandBy
RM
FAULT
R1 R2
ETHERNET Service Port
1
3
5
7
9
11 13 15 17 19 21 23
2
4
6
8
10 12 14 16 18 20 22 24
2
1
3
Summary of Contents for Hirschmann MACH1000 Series