26
Installation MACH1000
Release 07 08/2022
1.3.7
Connections for voltage-carrying lines
The supply voltage is electrically isolated from the casing.
A device has one or two internal power supply units. Each power supply unit
has a connection for the supply voltage and a connection for the signal
contact.
The power supply unit types have the following different properties:
Type of connections: terminal or plugged
Type of connectable supply voltages: DC or AC voltage
Level of connectable supply voltages:
For devices without PoE featuring 2 power supply units, you can connect the
supply voltage redundantly. Both inputs are uncoupled. With a non-
redundant supply of the supply voltage, the device reports the loss of a
supply voltage. You can prevent this message by applying the supply voltage
via both inputs, or by changing the configuration in the Management.
Note:
At positions 36 and 37 of the product code (see
table 1
) you find which
power supply types your device has.
The following tables provide an overview of the possible connections for
voltage-carrying lines:
1 Power supply unit 2
a
Possible types:
C DC voltage connectable
Voltage range:
See “General technical data” on page 52.
G
b
DC or AC voltage connectable
Voltage range:
See “General technical data” on page 52.
2 Power supply unit 1
Possible types:
C See 1
G See 1
3 Connection for the
signal contact
Spring-loaded terminal
2-pin
Table 4:
Connections for voltage-carrying lines:
rear view of the device variants with terminal connections
4 5
3
2
1
Relay 2
N L
4 5
3
2
1
Relay 1
N L
4 5
Relay 1
3
2
1
N L
1
2
3
4
5
Summary of Contents for Hirschmann MACH1000 Series
Page 67: ...Installation MACH1000 Release 07 08 2022 67 ...
Page 68: ......