![Belden GRASS VALLEY KMV-3901 Installation & Service Manual Download Page 95](http://html1.mh-extra.com/html/belden/grass-valley-kmv-3901/grass-valley-kmv-3901_installation-and-service-manual_2725589095.webp)
95
KMV-3901/KMV-3911
Installation & Service Manual
To configure a unicast IP address on the Kaleido-RCP2
1 Press and hold the ENTER button until the ESC button lights up, to display the
configuration menu.
2 Select ETHERNET OPTIONS on the LCD display, and then press ENTER.
3 Select
Unicast host IP
, and then press ENTER.
4 Select
Enable IP 1
, and then press ENTER.
The Enable IP x parameter instructs the Kaleido-RCP2 to query the selected IP address
for a list of rooms.
5 Select
Host IP ADDR
, and then press ENTER.
6 Using the numeric keypad, type the IP address of a Kaleido multiviewer on a remote
subnet, and then press ENTER.
to add unicast IP addresses for up to three remote Kaleido
multiviewer systems.
Logging on to the Kaleido-RCP2
As a network device, the Kaleido-RCP2 provides access to any room configuration on any
Kaleido multiviewer system on the network. As a security measure, access is controlled by a
login procedure.
To log on to a Kaleido multiviewer system from the Kaleido-RCP2
1 Press the LOGIN key.
The following message will appear on the LCD display:
LOGIN Position
Admin
2 Press ENTER to select “Admin”.
A message prompting you to enter a password will appear on the LCD display.
3 Press ENTER again (by default, there is no password).
The message “Access granted” will appear on the LCD display if the login is successful. If
a mouse is connected to the Kaleido-RCP2, then you should be able to see and move
the mouse pointer on the monitor wall.
For more information, refer to the
Kaleido-RCP2 Guide to Installation and Operation
. See
Note:
If at any time the message “Target system is offline” or “No login list
available” appears on the LCD display, press the ESC, ENTER and DEL keys
simultaneously and go back to
.