18
Installation
Mechanical Installation of KMV-3901/3911 Cards in the Densité Frame
Mechanical Installation of KMV-3901/3911 Cards in the Densité
Frame
The KMV-3901/3911 and its associated rear connector panel must be mounted in a Densité
3 frame or a Densité 3 mini frame. It is not necessary to switch off the frame’s power when
installing or removing the card. Refer to the Densité 3 frame manual or the Densité 3 mini
frame manual for detailed instructions on installing cards and their associated rear panels.
See
To set up the multiviewer hardware
1 Referring to the Guide to Installation and Operation that shipped with your
Densité 3+ FR1, Densité
3 mini
or
Densité 3
housing frame, mount the KMV-3901/3911
multiviewer card and associated rear panel in the housing frame, and then power up
the frame.
Leave the frame door open so that you can monitor all the card’s LEDs.
The KMV-3901/3911 card starts up. The startup sequence takes approximately five
minutes, during which time the Status LED is blinking orange. See
Once the startup has completed, the Status LED should be red (steady) because the
card is not connected to the network yet:
IMPORTANT
Keep the KMV-3901/3911 offline at initial setup to avoid conflicts.
Before powering up the Densité housing frame, make sure none of the KMV-
3901/3911multiviewer cards it contains are connected to the network, to
avoid IP-address conflicts during initial physical setup
—
i.e. make sure there
is no cable connected to your cards’ ETH port.
Densité CPU-ETH2 Enhanced Ethernet Controller Card
A Densité frame housing a KMV-3901/3911 multiviewer card must have a
controller card (Densité CPU-ETH2 Enhanced Ethernet Controller Card) with
firmware version 2.0.4 or later. A controller with an earlier version of the
firmware cannot provide a time reference to the multiviewer card. Make sure
the controller’s internal clock is set to the correct date and time. The clock
settings will persist for 10 days after a power loss. Should you need to change
the time on a Densité CPU-ETH2 controller, then make sure to restart all
multiviewers located in the same housing frame as the controller card. Refer
to the Densité CPU-ETH2 Enhanced Ethernet Controller Card Guide to
Installation and Operation for more information.
See
Note:
For more information on the card’s LEDs, see
Green
Blinking orange
Red
Blinking red
Normal
Booting (or the card is
selected for local control)
No Ethernet / SD card
error
Fan failure / no rear /
duplicate IP address