81
KMV-3901/KMV-3911
Installation & Service Manual
Card LED, Overall alarm and GSM contribution
The
Card LED
,
Overall alarm
and
GSM contribution
columns contain lists that allow you to
set the level of contribution of each individual alarm to the alarm named in the column
heading.
Card LED
This column allows you to configure the behavior of the KMV-3901/3911’s card-
edge status LED.
Overall alarm
This column allows you to configure the contribution of each individual alarm
to the
overall alarm
associated with this card. Indicators for the overall alarm
appear in the upper left corner of the control panel windows, and at the
bottom of the
Status/Name
column.
GSM
contribution
This column allows you to configure the contribution of each individual alarm
to the GSM alarm status associated with this card. The GSM is a dynamic
register of all iControl system alarms, and is also an alarm provider for external
applications. The possible values for the GSM contribution are related to the
overall alarm contribution:
• If the overall alarm contribution is set to
Disabled
, then the GSM alarm
contribution can be set to any available value.
• If the overall alarm contribution is set to any level other than disabled, then
the GSM contribution follows the overall alarm.
Alternatively, select the
Overall alarm and GSM contribution follow card LED
check box, to have the same contribution in all three contexts for the
corresponding individual alarm.
Note:
N/A
means the alarm is not user-configurable.
Overall
alarm
indicators