BAL2185_Grease_lubrication_pump_PICO_with_PICO-troniX1_-tronic_0519EN 10158410
...a product of
© BEKA 201 All
!
9
rights reserved
56
14.
Spare part list and drawing
Spare part lists and drawings are available on request.
Please indicate the article number of the device in order to obtain them.
Signal indicators
Function
Error
Lubrication deficit
ON
ON
OFF
OFF
LED red
LED green
1 s 1 s 1 s
1 s
Error
Level too low
(only for devices with follow-up
piston)
ON
ON
OFF
OFF
LED red
LED green
1 s 1 s
Trial lubrication (permanent
lubrication); In order to initiate a
permanent lubrication for service
purposes in the operational mode of
time-dependent lubrication duration,
the lubrication duration has to be set
higher than the cycle duration.
Until lubricant is refilled
ON
OFF
LED red
ON
OFF
LED green
Revolution error in operational mode
of revolution-dependent lubrication
duration
ON
OFF
LED red
ON
OFF
LED green
1 s 1 s
Error
System pressure too high
ON
ON
OFF
OFF
LED red
LED green
1 s
1 s