BAL2185_Grease_lubrication_pump_PICO_with_PICO-troniX1_-tronic_0519EN 10158410
...a product of
© BEKA 201 All
!
9
rights reserved
60
16.2
Code for devices with integrated control unit PICO-tronic
Contruction type no.
2185
Motor voltage
12 V DC
24 V DC
with Hirschmann plug-type connection
1
2
Pump elements*
Outlet position
without
PE-120 F
PE-120 FV
PE-120 F (pos. ) + PE-120 FV (pos. )
4
10
PE-120 F (pos. ) + PE-120 FV (pos. )
10
4
4
10
4+10
0
0
0
1
2
3
4
5
6
-
-
7
-
-
8
Reservoir capacity (l)
Effective volume (l)
1,5
1,2
Version with follow-up piston
Version with agitator blade
1
4
Integrated control unit
PICO-tronic
Code no.
6
Additional functions
Time-dependent cycle duration
0,5 - 8 h
1 - 16 min
2 - 32 min
2 - 32 h
Time-dependent
lubrication
Pulse-
dependent
Revolution-
dependent
lubr. duration
1 - 16 min
2 - 32 min
2 - 32 s
1 - 16 pulses
17 - 32 pulses
33 - 48 pulses
1 - 16 rev.
10 - 160 rev.
170 - 320 rev.
21
22
23
25
2A
2B
2C
2E
24
29
2D
2J
30
3A
31
32
36
3J
37
38
3C
3K
3D
3E
51
52
53
55
5A
5B
5C
5E
5L
5M
5N
5R
Pulse-dependent cycle duration
1 - 16**
20 - 320** 100 - 1600** 500 - 8000**
10 - 160**
Time-dependent
lubrication
Pulse-
dependent
Revolution-
dependent
lubr. duration
1 - 16 min
2 - 32 min
2 - 32 s
1 - 16 pulses
17 - 32 pulses
33 - 48 pulses
1 - 16 rev.
10 - 160 rev.
170 - 320 rev.
26
27
28
2K
2L
2F
2G
2H
2M
2N
2K
2L
2P
2Q
2R
33
34
35
3K
3L
39
3A
3B
3M
3N
3F
3G
3H
3P
3R
56
57
58
5J
5V
5F
5G
5H
5W
5X
5S
5T
5U
5Y
5Z
Parameters
external status signal
as error signal
as OK-signal
with system pressure monitoring***
with line break monitoring***
without monitoring
1
2
3
5
4
6
Special version
Code no.
000
* with pressure limiting valve
** pulses
2185 . X . X . X . 6 . XX . X . XXX
*** not selectable together with pulse-dependent cycle duration
duration
lubr. duration
duration
lubr. duration