© BEKA 201
!
9 All rights reserved
BAL2185_Grease_lubrication_pump_PICO_with_PICO-troniX1_-tronic_0519EN 10158410
...a product of
19
C)
Filling via the filling set PICO Fill
The filling set PICO Fill (order no.: 208103027) has been developed for an easy and quick filling of the device. It consists
of a filling connection M20x1,5 (order no.: 21520152) and a filling gun (order no.: 208103026).
Remove the screw plug from the outlet 4 or 10 (see fig. 4 in chapter 6.3 „Assembly of the pump elements“) and screw in
the filling connection M20x1,5.
Operate the filling gun until the lubricant leaks out visibly at the outlet (approx. 10 mm, see fig. 17).
Connect the filling gu
the filling connection M20x1,5 and fill the device up to the maximum level.
n to
Remove the filling connection M20x1,5 after finishing the filling process and screw the screw plug, which had been
removed earlier, back in.
Fig. 17:
7.3
Check of rotational direction of the device
·
Compare the rotational direction of the agitator blade with the directional arrow on the level sticker (see fig. 18) for
devices with agitator blade.
·
Check the electrical connections of the device at a wrong rotational direction and change these if necessary.
The
and the
will be
when they are operated in the
motor
damaged
wrong rotational
device
direction
for a longer time!
Fig. 18:
Level max.
10 mm
Lubricant
Filling gun
Caution!
Directional arrow
on level sticker