10.2
Lubricant change
Pay attention to utmost
when refilling lubricant!
cleanness
·
Check the level regularly and refill clean lubricant as necessary, see chapter 7. „Start up“.
·
Change the lubricant according to the specifications of the lubricant manufacturer. Environmental influences like
increased temperature or pollution may shorten these intervals!
·
Please make sure to only use lubricants that are suitable for the device as well as the lubricated machine and that
comply with the requirements of the particular operating conditions.
·
In case of
, ensure that the lubricant
corresponds to the quality of the
different lubricant manufacturers
quality
previously used one!As precautionary measure, drain the lubricant reservoir properly and clean it!
10.3
Changing the integrated control unit
A)
Disconnect the device from the power supply (pos. 1, see fig. 54) and secure it against recommissioning.
Fig. 54:
Caution!