9.2.13 Special function
Cycle locked
With the special function
, the function of the lubrication system can be easily locked by an external sensor
Cycle locked
(such as PLC or board computer). This special function is needed for lubrication systems which are to lubricate machine
or vehicle parts only when these are in operation.
If the machine or vehicle parts are temporarily taken out of order, the cycle is locked. The green LED in the inspection
window of the protective housing (see fig. 40) starts to flash (see chapter 13.2 „Signal indicators of the integrated control
unit PICO-tronic").
If this case happens during the lubrication duration, the lubrication is finished. The cycle is locked afterwards. The cycle is
ended normally when the lock is lifted.
If th case happens outside the lubrication duration, the cycle is stopped at this point. The cycle is continued where i was
is
t
interrupted when the lock is lifted.
The special function
is not displayed by the special function
C
E
ycle locked
xternal status signal
and cannot be selected at the same time as the special function
Adjustment to operating
conditions
.
9.2.14 Error
Lubrication deficit
The error
occurs when a lubrication cannot be finished during a cycle sequence. In this case, the device
Lubrication deficit
needs more time for processing the lubrication duration than there is time available by the length of the cycle duration. If
this case occurs in several cycles in a row, the integrated control unit
an error (see chapter 13.2 „Signal indicators
reports
of the integrated control unit PICO-tronic"). However, the integrated control unit does not switch off the device because a
lubrication deficit is better than no lubrication.
The integrated control unit automatically resets the error when a complete lubrication is finished within a following cycle.
10.
Maintenance
Disconnect the device from power supply before
.
maintenance or repairs
Only carry out
in
and
.
maintenance and repair complete device standstill
pressureless condition
Check the surface temperature of the device to avoid the risk of burns by radiant heat. Wear heat-resistant
gloves and safety goggles! Clean soiled or contaminated surfaces before maintenance, wearing protective
equipment if necessary! Secure the device against recommissioning during maintenance and repair work!
10.1
General maintenance
·
Retighten all fittings 6 weeks after start up!
·
Check all components for leakages and damage at least every four weeks!
If leakages are not repaired, lubricant
. Remove possible puddles of
might escape under high pressure
lubricant immediately.