© BEKA 201
!
9 All rights reserved
BAL2185_Grease_lubrication_pump_PICO_with_PICO-troniX1_-tronic_0519EN 10158410
...a product of
49
B)
Remove the three hexagon socket head cap screws (pos. 1, see fig. 55) using anAllen keyAF 3.
Fig. 55:
C)
Remove the protective housing (pos. 1, see fig. 56) and loosen the receptacles of the connection cables (pos. 2
and pos. 3, see fig. 56).
Make sure that the connection cables do not tear off!
Fig. 56:
D)
Attach the receptacles of the connection cables at the new control unit. The red connection cable at the red
receptacle (pos. 2, see fig. 56) and the green connection cable at the green receptacle (pos. 3, see fig. 56).
1
Caution!
1
2
3