35
9.1.1
Functional description
Fig. 36:
Alubrication starts at initial connection of the integrated control unit.
Each time after the voltage (ignition) is switched on, the red and the green LED glow for approx. 1.5 seconds in the
inspection window of the protective housing and display the operational capability of the integrated control unit.
If the voltage is interrupted (ignition switched off) during the cycle sequence or during the lubrication duration, the data is
stored in the operational database of the integrated control unit. When the voltage (ignition) is switched on again, the
cycle sequence starts where i was interrupted before.
t
When the voltage is switched on, an intermediate lubrication can be triggered at any time by pushing the push-button for
intermediate lubrication. The current data of the cycle is deleted and a new lubrication cycle starts immediately.
Some errors have to be reset after the troubleshooting by pushing the push-button for intermediate lubrication (see
chapter 13. „Troubleshooting“).
Then, the device immediately starts with a lubrication cycle.
LEDs for indicating
the functional state
Grid switch for setting
the cycle duration
PICO-troniX1
Schmierzeit
Lubrication time (min)
16
1
8
0,5
Zykluszeit / Cycle time (h)
Service
8
0,5
Zykluszeit / Cycle tim
e (h)
Service
8
0,5
Zykluszeit / Cycle time (h) Service
Connector bushing for the
diagnosis software
BEKA-DiSys
Grid switch for setting the
lubrication duration
Adhesive label in inspection
window (example)
Connection
bayonet plug
7-pole
Connection
Hirschmann plug
7-pole
Push button for
intermediate
lubrication
Inspection window
of the protective
housing
Frame of the