BAL2185_Grease_lubrication_pump_PICO_with_PICO-troniX1_-tronic_0519EN 10158410
...a product of
© BEKA 201 All
!
9
rights reserved
38
Setting ranges of the revolution-dependent lubrication duration:
·
1 to 16 revolutions (16 notches à 1 revolution)
·
10 to 160 revolutions (16 notches à 10 revolutions)
·
170 to 320 revolutions (16 notches à 10 revolutions)
The revolution-dependent lubrication duration can be set (within a setting range) using the left grid switch in the
inspection window of the protective housing (see fig. 36).
9.1.6
Function
Level monitoring
See chapter 8.6 „Level monitoring“.
9.2
PICO-tronic
The
can be determined
or
for the integrated control unit PICO-tronic.
cycle duration
time-
pulse-dependently
The
can be determined
or
.
lubrication duration
time-, pulse-
revolution-dependently
Functions:
The following functions can be evaluated with the integrated control unit:
·
System pressure monitoring (monitoring of the line pressure in the lubrication system)
·
Level monitoring (only for devices with follow-up piston, see chapter 8.6 „Level monitoring“)
·
Line break monitoring (monitoring of the lines in the lubrication system)
The functions
and
cannot be selected in
S
L
ystem pressure monitoring
ine break monitoring
the operational mode of
and
be selected
pulse-dependent cycle duration
cannot
at the same
time
.
Special functions:
The following special functions can be used with the integrated control unit:
·
External status signal as error signal (signal, when an error occurs) or OK-signal (signal, when everything is alright)
·
Adjustment to operating conditions
·
Cycle locked (lock of the cycle sequence when the machine part or vehicle part, that is to be lubricated, is temporarily
out of order)
The special function
and
be selected
Adjustment to operating conditions
Cycle locked
cannot
at the same time
.
Notice!
Notice!