configurAtion StepS
Behnke AT6 manual
*87*
00 to 25 # Delay
Delay time until the emergency call is
activated after pressing the emergency
call button (default = 05 seconds).
*92*
0 to 3 #
Automatic disconnection
Disconnects the connection if the emer-
gency call recipient has been silent for
longer than the set time.
0 = off (default, no automatic discon-
nection)
1 = 30 seconds
2 = 60 seconds
3 = 90 seconds
Emergency call protocol settings
*01*
#
ID code for P100
The ID code for P100 always consists of
8 digits
*02*
#
ID code for CPC
The ID code for CPC consists of 6 - 8
digits
*03*
#
ID code for Q23
The ID code for Q23 always consists of
12 digits
*21*
*22*
*23*
*24*
0 to 3 #
0 to 3 #
0 to 3 #
0 to 3 #
Type of the 1st phone number
Type of the 2nd phone number
Type of the 3rd phone number
Type of the 4th phone number
Following options are available for the
protocols for each phone number:
0 = P100
1 = LANGUAGE (no protocol, default)
2 = Q23
3 = CPC
Summary of Contents for 99-1025