69
led diSplAy on BuS unit
Behnke AT6 manual
Strictly according to EN81-28 (alternative setting parameter *78* to 1)
Emergency call state
inactive
Last routine test OK
Emergency call state
inactive
Last routine test not OK
*
Emergency call state active
Waiting for connection,
last emergency call still
open
(Please wait)
Emergency call state active Connection established
(Please speak)
*
The pictograms in the cabin flash alternately (one second on, one second off) when the last automatic routine test has failed. The
display automatically returns to normal at the next valid routine test. This either takes place automatically within the set interval or
can be repeated manually and immediately by means of parameter *94* on 2.
Key
= LED is off
= LED lights up
= LED flashes
= LED flashes slowly
= LED flashes quickly
= LED is off
= LED lights up
= LED flashes
= LED flashes slowly
= LED flashes quickly