74
remote configurAtion uSing A telephone
Behnke AT6 manual
Local connection with routine* and without protocol (Compliant to EN81-28)
1.
Start configuration:
0 0
2. Local destination phone
number:
* 1 1 * 1 1 2 #
Internal destination phone
number ending on 112
3. Redundant
destination phone
number:
* 1 2 * 0 1 5 1 2 3 4 5 6 7 8# Redundancy on emergency phone
4. Type of the 1st destination
phone number:
* 2 1 * 1 #
No protocol (voice call only)
5.
Type of the 2nd destination
phone number:
* 2 2 * 1 #
No protocol (voice call only)
6. Emergency call button
delay
(3 seconds):
* 8 7 * 0 3 #
Emergency call must be pressed
> 3 seconds
7.
Phone number for routine
test
*
:
* 1 7 * 1 1 3 #
Other phone number to dis-
tinguish emergency call and
routine. (All test calls must be
documented and responded to if
missed)
8. Routine tests every 3
days
*
:
* 2 7 * 3 #
Must be no longer than 3 days
apart
9. Record announcement for
emergency call (optional):
* 5 1 * "Emergency call in
elevator x" #
Announcement for emergency
call recipient, if there is no other
possibility for automatic assign-
ment.
10. Display mode strictly
adhering to EN81-28
* 7 8 * 1 #
Emergency call state must be
terminated with reset or key 5
11. Exit set-up mode:
* 0 0 * #
*
Routine tests can also be manually triggered by an elevator attendant on site at least every three days. These must then also be
documented.