Commissioning
EP7402-0057
33
Version: 1.3
4.1.4
Step 4: Test run
1. Ensure that all previous steps have been completed successfully.
2. Remove any load from the conveyor roller.
3. If the motor has a holding brake, release the holding brake: set
"Brake output" to 1.
4. Set "Velocity" to 50% of the nominal speed of the motor including gear unit:
Formula for calculating 50% of the nominal speed:
n: value for the "Velocity" output variable
n
N
: nominal speed of the motor in rpm
i: transmission ratio. (i = 1 if no gear unit
is used)
5. Set "Enable" to 1.
ð
The rotor is aligned for 1 second.
ð
The box then attempts to turn the motor.
6.