20
6) USB Port Connection
The TR400/OC400 terminal has a mini USB
data port to enable upgrading of the firmware,
advanced configuration, and data connection.
7) Connecting Power to the Terminal
The TR400/OC400 terminal can be powered from
the supplied AC Plug pack, or connected to an
external 10-32V DC power source.
ISD950 AC Plug Pack Installation
For installation using the ISD950 110-240 AC plug
pack, connect the 4-way Microfit connector from the
plug pack to the 4-way power connector on the rear
of the TR400/OC400 terminal. In this configuration
the ignition/accessory status is always ON.
DC Power Source Installation
The DC power cable has three wires, RED,
BLACK and YELLOW. The RED and BLACK
wires are used for the power connection, The
YELLOW wire can be connected to a circuit to
sync the ON/OFF status of the TR400/OC400
terminal with a vessels/in-building operation.
By default, the TR400/OC400 terminal will stay on
for 20 minutes after this input (YELLOW wire) is
switched OFF. If a call is in progress while this occurs,
the TR400/OC400 terminal will stay on for 20 minutes
after the call is terminated. Please follow the steps
below to connect the DC power cable to the battery
power and the TR400/OC400 terminal.
1.
Route the wire end of the DC power cable to
the connection point.
2.
Connect the BLACK wire to the negative
terminal of the battery or the vessel
chassis (if negatively grounded chassis).
3.
Connect the RED wire to the positive
terminal of the battery. It is recommended to
add the 5A fuse (supplied) between them.
4.
Connect the YELLOW wire to the vessel
accessory power or ON/OFF Switch wire. If
the accessory power is unavailable, this may
be connected to a vessel ignition voltage. It
is recommended to add a 1A fuse between
them. The accessory wire enables the TR400/
OC400 to turn on and off. If this function
is not required, the YELLOW wire MUST be
connected to the RED wire.
5.
Connect the 4-way Microfit connector on
the DC power cable to the 4-way power
connector on the rear of the TR400/OC400.
RED
(+) Vin 10 to 32VDC
BLACK
(-) OV Power Ground
YELLOW (IGN) Ignition / Accessory
To Battery Positive Terminal
(Requires 5A Fuse)
To Negative Terminal or chassis
To ON/OFF Switch
(1A Fuse recommended)
YELLOW
BLACK
RED