78
mi-4
Series
Advanced Entry Calibration (continued)
Step
Operator Action
Displayed Message
Comment
11
Using the Gain Number
data collected from Steps 9
and 10, subtract each Label
Value from the TOF Value.
From the resulting list of
Difference Values, select
the largest number. Its
associated Gain Number is
the best selection for the
media. See the example
from
mi-4212
below.
""]<<<_
JQQHQLTRI
-OR-
"]<<<_
JQQHQLTRI
Where ‘yyy’ is
a numerical
value
representing the
current sensor
reading.
Both sensor
readings must
be above 20.
Gain Number
Label Value
TOF Value
Difference Value
00
255
254
1
01
251
240
11
02
241
213
28
03
231
182
49
04
219
150
69
05
212
119
93
06
200
88
112
07
189
58
131
08
178
32
146
09
167
20
147
10
156
17
139
11
146
16
130
12
136
15
121
13
126
15
111
…
…
…
…
30
116
14
102
31
112
14
98
Example from the data compiled in the table above: Gain Algorithm
Number 8 should be used because it has the highest difference value
(146) where both the Label Value and the TOF Value is above 20.
(Continued next page)
Summary of Contents for 4206
Page 1: ...Meto mi 4 Label and Tag Printer Extended Operating Manual B a r c o d e S y s t e m s ...
Page 5: ......
Page 7: ...ii ...
Page 9: ...iv ...
Page 11: ...vi ...
Page 12: ...vii ...
Page 13: ......
Page 17: ...4 mi 4 Series ...
Page 20: ...mi 4 Series 7 ...
Page 32: ...mi 4 Series 19 ...
Page 44: ...mi 4 Series 31 ...
Page 50: ...mi 4 Series 37 Continued next page ...
Page 56: ...mi 4 Series 43 ...
Page 58: ...mi 4 Series 45 ...
Page 62: ...mi 4 Series 49 ...
Page 74: ...mi 4 Series 61 ...
Page 78: ...mi 4 Series 65 Continued next page ...
Page 80: ...mi 4 Series 67 ...
Page 82: ...mi 4 Series 69 ...
Page 84: ...mi 4 Series 71 ...
Page 86: ...mi 4 Series 73 ...
Page 111: ...98 mi 4 Series ...
Page 114: ...mi 4 Series 101 ...
Page 139: ...126 mi 4 Series Continued next page ...
Page 142: ...mi 4 Series 129 ...
Page 144: ...mi 4 Series 131 ...