14/4798.495.002
10 | Introduction
Dachs Pro 20 ST
1.5.2 Responsibilities of the operator
The operator is obliged to provide the necessary constructional requirements for assembly and commissioning as well as for
safe and intended use of the systems.
Furthermore, the operator is obliged and solely responsible for the registration, notification and operation of the unit in
accordance with applicable regulations.
The installer is obliged to adhere to the national laws, regulations and standards of the respective country of the installation
location. Among others, these include the following:
●
The provisions of the applicable building law.
●
The fire protection regulations.
●
The technical requirements for the gas supply connection.
●
The safety instructions in accordance with DIN, DVGW, VDE, TAB and the EU.
●
Stipulations for the erection of power plants with a nominal voltage of up to 1000V.
●
The operation of electrical units.
Note:
Outside of Germany, apart
from national regulations, the
international standard IEC 60364
Electrical Installation of Buildings
is to
be complied with.
i
Notification and authorisation obligation
Global and local regulations and TCR (technical connection requirements) of:
●
Electric utility/distribution network operators (DNO)
●
Gas suppliers (GS)
●
Water authorities
●
Chimney sweeps
●
Building inspection
●
Main customs office
are to be observed with regard to registration obligations. In case of technically justifiable deviations from these local
regulations, an approval by the responsible supplier is to be obtained before installing the Dachs Pro 20 ST.
Prior to commissioning:
●
A leakage test of the gas duct according to TRGI must be carried out.
●
The exhaust gas system is to be approved by the responsible master chimney sweep, i.e. the authority responsible
for inspecting gas installations (e.g. in the case of shared chimneys).
●
A frost-protected operation of the unit is to be ensured. This means that suitable frost protection measures
adapted to the ambient conditions have to be implemented.
●
It is to be ensured that the heating water quality complies with the required specifications of the manufacturer.
●
It is to be ensured that the fuel corresponds to the required gas category.
Summary of Contents for Senertec Dachs Pro 20 ST
Page 115: ...14 4798 495 002 Spare parts 115 Dachs Pro 20 ST Notes ...
Page 116: ...14 4798 495 002 116 Spare parts Dachs Pro 20 ST Notes ...
Page 117: ...14 4798 495 002 Spare parts 117 Dachs Pro 20 ST Notes ...
Page 118: ...Dachs Pro 20 ST Baxi Commercial Wood Lane Erdington Birmingham B24 9QP ...