cable.
11.
Pull each cable taut. Push the cable
adjusters hard up against the back panel. The
end of the cable adjuster will pass into the hole.
Tighten the screws in the adjusters so that they
clamp the cables in position. Apply tension to
the cables by turning the hexagonal adjusters by
hand (See figure 19).
12.
Inspect the installation of the hotbox against
the fireplace surround. If the hotbox is aligned
squarely and the sealing is satisfactory, fully
tighten the cable adjusters.
13.
If the hotbox is not correctly aligned,
release the tension on the cables by slackening
the screws and turning the hexagonal adjusters
fully anticlockwise. The hotbox should then
automatically realign itself. Pull each cable taut
again and push the cable adjusters back against
the back panel. Again, tighten the screws in the
adjusters and apply tension to the cables by
turning the hexagonal adjusters clockwise as far
as possible.
14
.
Feed the free length of the cables into the
gap between the inner and outer back panels so
that they are available to allow easy removal and
refitting of the appliance during subsequent service
calls.
Do not cut off the free lengths of cable.
On
precast flue installations feed the cables into the
small holes at the base of the side panels (See
figure 19)
9.3 Sealing floor front - All installations.
Using the floor sealing tape supplied, seal the
bottom of the hotbox to the fireplace and hearth
floor (See figure 20).
Make sure that the whole length of the front
edge of the hotbox is fully sealed.
Page 26
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Figure 20. Floor sealing
Figure 19. Lower cable retention
Side entry
Rear entry