17.1 Checking the aeration setting of the burner.
1.
The aeration shutter is factory set. It is
important to ensure that the aeration setting
is correct for the ceramic fuel effect used
(See figure 35).
2.
To adjust the aeration setting to suit the
fuel effect used, loosen the two aeration
shutter screws, slide the aeration shutter to
the desired position and tighten the fixing
screws.
17.2 To remove the Westminster and
Bolero fascia.
1.
Remove the bottom front cover and the fire
front casting.
2.
Remove the two screws securing the bottom of
the fascia to the sides of the hotbox (See figure
36). On the Bolero there is also two washers.
3.
Carefully lift the fascia upward to clear the
upper retaining brackets on the hotbox - (See
figure 36). Pull the fascia clear and place carefully
aside.
4.
Refit in the reverse order. Make sure that the
fascia is properly located over the upper retaining
brackets. See section 12 of this manual for detailed
fitting instructions.
17.3 To remove the Victorian fascia.
1.
Remove the bottom front cover and the fire
front casting.
2.
Hold the sides of the fascia and lift clear of the
support brackets (See figure 37).
3.
Refit in the reverse order. Make sure that the
fascia is properly located over the upper and
lower retaining brackets. See section 12.3 of this
manual for detailed fitting instructions.
Page 37
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Figure 37. Front casting removal
Figure 36. Removing the fascia
fixing screws (Shown with
Bolero fascia)
Figure 35. Aeration shutter settings for