6. IGNITION CHECK
Before attempting to install, it is worth checking that the ignition system performs
satisfactorily.
Set the control knob to the off
position.
Depress the control knob and rotate
it anticlockwise to the pilot ignition
position. A 'click' will be heard as
the integral piezo operates. A spark
should be seen between the electrode
and pilot tip
.
If there is no spark
check the following: -
!
Ensure that the electrode lead is connected to the terminal at the base of the
electrode.
!
If the above is correct, check for damage to the electrode lead.
7. GAS SUPPLY CONNECTION
A nut and olive are provided for an 8mm pipe inlet connection to the inlet elbow at the
bottom front of the appliance. The elbow can be rotated to allow a connection from any
direction. The elbow includes a valve for isolating the gas supply and a pressure test
point.
The supply pipe must be rigid material. Flexible pipe must not be used.
Concealed supply pipe connection
If a concealed connection from inside the fireplace is required then
,
before the
appliance is fitted into the fireplace
it will be necessary to extend the supply line so
that it will project through the hole in the back of the hotbox and run to the inlet elbow
at the front. The pipe run from the supply line up to the rear opening in the hotbox must
be kept away from the area which will be taken by the hotbox when it is installed (See
figure 7).
Note that the centre of the appliance inlet elbow is 25mm above the fireplace floor. The
inlet elbow ‘G’ should be fitted to the supply pipe at this stage.
Page 21
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Figure 8. Ignition operation