6.2.3. Connection assignment of D-SUB plug
Pin
Assignment
1 --
2 CAN_L
3 CAN_GND
4 --
5 --
6 GND
B
7 CAN_H
8 --
9 UB
6.3. Display elements (status display)
Depending on the design, a DUO-LED may be integrated on the back of the encoder.
LED green
LED red
Status
off
off
Supply Voltage Not Connected
flashing off
Preoperational
Mode
on off Operational
Mode
on on Stopped/Prepared
Mode
off flashing
Warning
off on Error