Manual_GXP5_417_Lift_EN.doc
26/41
Baumer IVO GmbH & Co. KG
04.05.11
Villingen-Schwenningen,
Germany
Object 2100
Baud Rate
Subindex 0
Data Type
Unsigned 8
Access ReadWrite
Default
2 = 50kBaud
EEPROM Yes
Description
Read or set new sensor baud rate.
Æ
After setting, parameters must be saved in EEPROM with Object
1010h and then sensor must be reinitialized
Values 0
10
kBaud
1 20
kBaud
2 50
kBaud
3 100
kBaud
4 125
kBaud
5 250
kBaud
6 500
kBaud
7 800
kBaud
8 1000
kBaud
Object 2101
Node-ID
Subindex 0
Data Type
Unsigned 8
Access ReadWrite
Default 1
EEPROM Yes
Description
Read or set new sensor Node-ID.
Æ
After setting, parameters must be saved in EEPROM with Object
1010h and then sensor must be reinitialized
Values
1 - 127
Object 2110
Manufacturer_Options
Subindex 0
Data Type
Unsigned 32
Access ReadWrite
Default 8h
EEPROM Yes
Description
Settings for ensuring compatibility to older sensors
Values
Bit 3 =1 : Reset after Bus Off