Object 63C4 Supported Warnings
Subindex 1
Data Type
Unsigned 16
Access ReadOnly
Default Multiturn:
14h
EEPROM No
Description
Warnings supported by Object 63C5
Values Multiturn:
Bit 2 = CPU Watchdog status
Bit 4 = Battery charge
Object 63C5 Warnings
Subindex 1
Data Type
Unsigned 16
Access ReadOnly
Default 0h
EEPROM No
Description
Warnings as per Object 63C4
Values Multiturn:
Bit 2 = 1
Æ
CPU Watchdog reset
Bit 4 = 1
Æ
Battery charge is insufficient
Object 63C6 Supported Alarms
Subindex 1
Data Type
Unsigned 16
Access ReadOnly
Default 1h
EEPROM No
Description
Alarm messages supported by Object 63C7
Values
Bit 0 = Position error
Object 63C7 Alarms
Subindex 1
Data Type
Unsigned 16
Access ReadOnly
Default 0h
EEPROM No
Description
Alarm messages as per Object 63C6h
Values
Bit 0 = 1
Æ
Position error active