Overview
The following table provides a summary of the various transmission types of PDOs:
1906h
Sub2
Sub5
2800h
Brief Description
FFh
3ms
0
Cyclical transmission every 3 ms
FFh
5ms
2
The PDO is sent double every 5 ms if a change is present.
FFh
0ms
0
PDO transmission is deactivated
FFh
0ms
2
PDO transmission is deactivated
3
xxx
0
Transmit for every third Sync telegram
3
xxx
2Bh
Every third Sync telegram, but only 43 times total (=2Bh).
PDO
PDO1 telegram structure:
ID
DLC
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
18Ch
4 Xx Xx Xx Xx Xx Xx
ID
: 17Bh+ Lift number * 10 + PosUnit
Length
: 6 data bytes
Byte1 - 4
: Current position in increments
Byte 5 - 6
: Speed
3.4.5. Emergency service
Internal device error or bus problems trigger an emergency message:
COB-ID
DLC Byte0 Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Error Code
80h+Node-ID 8
00h 01h
Error Register
1001h
Alarms 63C7h
Warning 63C5h
n.u.
Byte 0..1: Error Codes
Error Code (hex) Meaning
0000
Error Reset or No Error
1000 Generic
Error
Byte 2: Error Register
Bit
Meaning
0 Generic
Error
Byte 3..4 Alarms
Bit
Meaning
Value = 0
Value = 1
0
Position error active
No
Yes
Byte 5..6 Warning
Bit
Meaning
Value = 0
Value = 1
2
CPU watchdog status
OK
Reset carried out
4
Battery charge
OK
Charge too low
Byte 7: Not in use