Manual_GXP5_417_Lift_EN.doc
21/41
Baumer IVO GmbH & Co. KG
04.05.11
Villingen-Schwenningen,
Germany
Object 1005
COB-ID SYNC Message
Subindex 0
Data Type
Unsigned 32
Access ReadWrite
Default 80h
EEPROM Yes
Description
Defines COB-ID of synchronization object (SYNC)
Values
Bit 31
Not defined
Bit 30
1=Sensor generates SYNC messages, 0 = generates no
SYNC
message
Bit 29
1 = 29-bit SYNC COB-ID (CAN 2.0B), 0 = 28-bit SYNC
COB-ID (CAN 2.0A)
Bit 28..11 Bit 28 - 11 of 29-bit SYNC COB-ID
Bit 10..0 Bit 10 - 0 of SYNC COB-ID
Object 1008
Manufacturer Device Name
Subindex 0
Data Type
Unsigned 32
Access ReadOnly
Default "GXP5"
EEPROM No
Description
Device designation in ASCII
Values
Data 0 - 3:
"GXP5" = 47h 58h 50h 35h
Æ
GXP5W Multiturn
Object 1009
Manufacturer Hardware Version
Subindex 0
Data Type
Unsigned 32
Access ReadOnly
Default
EEPROM No
Description
Hardware version in ASCII
Values
Data 0 - 3 example:
31h 2Eh 30h 30h
= "1.00“
Object 100A Manufacturer Software Version
Subindex 0
Data Type
Unsigned 32
Access ReadOnly
Default
EEPROM No
Description
Software version in ASCII
Values
Data 0 - 3
See rating plate