Manual_GXP5_417_Lift_EN.doc
27/41
Baumer IVO GmbH & Co. KG
04.05.11
Villingen-Schwenningen,
Germany
Object 2201
Statistics
Subindex 0
Data Type
Unsigned 8
Access ReadOnly
Default 3h
EEPROM No
Description
Largest supported Subindex
Values 3
Subindex 1
Data Type
Unsigned 32
Access ReadOnly
Default 0h
EEPROM Yes
Description
Total number of position errors
Values 0...4294967295
Subindex 2
Data Type
Unsigned 32
Access ReadOnly
Default 0h
EEPROM Yes
Description
Total operating time in seconds (Object 6508h Time since last Reset)
Values 0...
4294967295
Subindex 3
Data Type
Unsigned 32
Access ReadOnly
Default 0h
EEPROM Yes
Description
Watchdog Timer Reset counter
Values
0 - 4294967295
Object 2300
Customer EEPROM Area
Subindex 0
Data Type
Unsigned 8
Access ReadOnly
Default 8h
EEPROM No
Description
Any desired data can be saved in this object
Values 8
Subindex
1 - 8
Data Type
Unsigned 16
Access ReadWrite
Default 0h
EEPROM Yes
Description
One 16-bit value can be saved per Subindex
(saving in EEPROM with Object 1010h)
Values 0