Operating manual for
BAUER RAINSTAR
Series TX Plus
32
6.7.5 STOP
At the end of the irrigation run the shut-off sensor is activated through shut-off frame and shut-off rods.
Sensor in shut-off position
As a result the turbine stops and the shut-off valve overpressure closes slowly and remains in this position until the
next operation.
If the RAINSTAR is connected to a hydrant you can release the water pressure which is remaining in the line after
closing the hydrant by pushing the „START-RESET“
key.
The shut-off valve opens and pressure is released through the PE-pipe.
If a low-pressure shut-off valve is mounted, it opens quickly.
It closes again after approx. 15 min.
By pressing the key „STOP“
the irrigation process can be stopped at any time.
The turbine flap opens (the turbine stops), the over-pressure shut-off valve closes, the low-pressure shut-off valve
opens.
The laid down PE – pipe length remains saved. It is set to 000 only when the shut-off sensor is actuated ( shut-off
position).
ATTENTION !
If the „STOP“ key is used while retraction on a machine without shut-off valve the retraction stops but the sprinkler
is still in operation. In order to prevent “over irrigation” around the sprinkler the machine should only work for a
limited period of time without retraction. Then start the machine again by pressing the„START“ key!!
ATTENTION
!
With machine data adjustments Pos. 12, adjustment „0“, the retraction stops only for a short period of
time when pressing „STOP“ key. After a few seconds the retraction starts again automatically.
ATTENTION: when working on the machine the whole drive needs to be switched off!!
STOPPING THE CONTROL FUNCTIONS,
By pressing the keys „STOP“ and „PROG.“ at the same time all functions of the ECOSTAR stop, this means that
the regulating motors of the turbine and the shut-off valve remain in their current position. With this combination of
keys the turbine regulation is stopped when the turbine rotation speed is low in order to change gears.