6.6 STOP - SENSOR
The machine can only work if the stop sensor is activated or in operating position.
Operating position
Shut-off position
The Stop - Sensor has three functions:
1.
Reset for the laid-down PE-pipe length:
When operated the laid-down pipe length is set to zero.
2.
Post irrigation:
If the post-irrigation procedure is carried out at the end of the run (0 m laid-down PE-pipe length) the post-
irrigation function is activated first and then the
ECOSTAR
is shut-off.
In the standard program the post-irrigation is activated 8m before the irrigation ends.
3.
Prevents pulses to the regulating motor.
After the stop sensor is activated, no pulses are passed on to the regulating motor.
Press the key
MENU
2 x, to get to the display of menu 3. Her it shows if the speed sensors are working . The sign
shows if a magnet activated the two speed sensors.
Line four shows if motors 1 and 2 are switched off after they have reached their mechanical stop.
If sign shows and one motor has not
reached its end position there is a blockage on the inside of the turbine ( MOTOR 1 ) or the valve( MOTOR 2 ).
The motor switches off when the power consumption exceeds 4,7 ampere and appears on the display.
If the display shows a flashing MOTOR 1 it means that the motor is running
SPEED 30.0m/h
DOSE 22 mm
TIME 14:10 STOP 7:43
STATUS MOTOR 1
If the display shows a flashing MOTOR 2 it means that the motor for the shut off valve is running.
SPEED 30.0m/h
DOSE 22 mm
TIME 14:10 STOP 7:43
STATUS MOTOR 2
By pressing the key PROG/POWER ON
or the PE-Pipe is laid out, the electronics is activated again.
The battery is charged only if the electronics is activated. There is no charging when in standby.