AW00011916000
Physical Interface
Basler scout GigE
79
7.4
Cabling Requirements
7.4.1
Ethernet Cables
Use high-quality Ethernet cables. To avoid EMI, the cables must be shielded. Use of category 6 or
category 7 cables with S/STP shielding is strongly recommended. As a general rule, applications
with longer cables or applications in harsh EMI conditions require higher category cables.
Either a straight-through (patch) or a cross-over Ethernet cable can be used to connect the camera
directly to a GigE network adapter in a PC or to a GigE network switch.
Close proximity to strong magnetic fields should be avoided.
7.4.2
Standard Power and I/O Cable
A single cable is used to connect power to the camera and to connect to the camera’s I/O lines as
shown in Figure 38.
The end of the standard power and I/O cable that connects to the camera must be terminated with
a Hirose micro plug (part number HR10A-10P-12S) or the equivalent. The cable must be wired to
conform with the pin assignments shown in the pin assignment tables.
The maximum length of the standard power and I/O cable is at least 10 meters. The cable must be
shielded and must be constructed with twisted pair wire. Use of twisted pair wire is essential to
ensure that input signals are correctly received.
Close proximity to strong magnetic fields should be avoided.
The standard power and I/O cable is intended for use if the camera is not
connected to a PLC device. If the camera is connected to a PLC device, we
recommend using a PLC power and I/O cable rather than the standard power and
I/O cable.
You can use a PLC power and I/O cable when the camera is not connected to a
PLC device, if power for the I/O input is supplied with 24 VDC.
See the following section for more information on PLC power and I/O cables.
Summary of Contents for scout GigE
Page 4: ......
Page 50: ...Specifications Requirements and Precautions AW00011916000 40 Basler scout GigE...
Page 52: ...Installation AW00011916000 42 Basler scout GigE...
Page 66: ...Basler Network Drivers and Parameters AW00011916000 56 Basler scout GigE...
Page 80: ...Network Related Camera Parameters and Managing Bandwidth AW00011916000 70 Basler scout GigE...
Page 184: ...Image Acquisition Control AW00011916000 174 Basler scout GigE...
Page 206: ...Color Creation and Enhancement AW00011916000 196 Basler scout GigE...
Page 232: ...Pixel Data Formats AW00011916000 222 Basler scout GigE...
Page 354: ...Chunk Features AW00011916000 344 Basler scout GigE...
Page 358: ...Troubleshooting and Support AW00011916000 348 Basler scout GigE...
Page 367: ...AW00011916000 Revision History Basler scout GigE 357...
Page 368: ...Revision History AW00011916000 358 Basler scout GigE...