AW00011916000
I/O Control
Basler scout GigE
91
8 I/O Control
This section describes how to configure the camera’s two physical input lines and four physical
output lines. It also provides information about monitoring the state of the input and output lines.
For more detailed information about the physical and electrical characteristics of the input and
output lines, see Section 7.7 on
page 84
.
8.1
Configuring Input Lines
8.1.1
Assigning an Input Line to Receive a
Hardware Trigger Signal
You can assign the camera’s input lines to receive external hardware trigger (ExTrig) signals. The
incoming ExTrig signals can then be used to control image acquisition.
Section 9.4.5.2 on
page 117
, Section 9.5.3.4 on
page 127
and Section 9.6.3.4 on
page 139
explain
how to configure the camera to react to a hardware trigger signal and how to assign an input line to
receive the hardware trigger signal.
The default line assignments depend on the image acquisition control mode:
Standard mode:
By default, physical input line 1 is assigned to receive an ExTrig signal to serve
as the frame start trigger.
By default, physical input line 2 is assigned to receive an ExTrig signal to serve
as the acquisition start trigger.
Legacy mode:
By default, physical input line 1 is assigned to receive the ExTrig signal to
serve as the acquisition start trigger.
You can assign only one line to receive the ExTrig input signal.
Summary of Contents for scout GigE
Page 4: ......
Page 50: ...Specifications Requirements and Precautions AW00011916000 40 Basler scout GigE...
Page 52: ...Installation AW00011916000 42 Basler scout GigE...
Page 66: ...Basler Network Drivers and Parameters AW00011916000 56 Basler scout GigE...
Page 80: ...Network Related Camera Parameters and Managing Bandwidth AW00011916000 70 Basler scout GigE...
Page 184: ...Image Acquisition Control AW00011916000 174 Basler scout GigE...
Page 206: ...Color Creation and Enhancement AW00011916000 196 Basler scout GigE...
Page 232: ...Pixel Data Formats AW00011916000 222 Basler scout GigE...
Page 354: ...Chunk Features AW00011916000 344 Basler scout GigE...
Page 358: ...Troubleshooting and Support AW00011916000 348 Basler scout GigE...
Page 367: ...AW00011916000 Revision History Basler scout GigE 357...
Page 368: ...Revision History AW00011916000 358 Basler scout GigE...