Image Acquisition Control
AW00011916000
160
Basler scout GigE
signal based on the current exposure time parameter setting, the current size of the area of interest,
and the time it will take to readout the captured pixel values from the sensor.
The trigger ready signal is especially useful if you want to run the camera at the maximum
acquisition frame capture rate for the current conditions. If you monitor the trigger ready signal and
you begin acquisition of each new image immediately after the signal goes high, you will be sure
that the camera is operating at the maximum acquisition frame rate for the current conditions.
Fig. 65: Trigger Ready Signal
You should be aware that if the Acquisition Frame Rate Abs parameter is enabled, the operation of
the trigger ready signal will be influenced by the value of the parameter:
If the value of the parameter is greater than zero but less than the maximum allowed, the
trigger ready will go high at the rate specified by the parameter value. For example, if the
parameter is set to 10, the trigger ready signal will go high 10 times per second.
If the value of the parameter is greater than the maximum allowed acquisition frame rate with
the current camera settings, the trigger ready signal will work as described above and will go
high at a point that represents the maximum acquisition frame rate allowed.
By default, the trigger ready signal is assigned to physical output line 2 on the camera. However,
the assignment of the trigger signal to a physical output line can be changed.
For more information about changing the assignment of camera output signals to physical output
lines, see Section 8.2.1 on
page 93
.
For more information about the electrical characteristics of the camera’s output lines, see
Section 7.7.2 on
page 87
.
If you attempt to start an image acquisition when the trigger ready signal is low,
the camera will simply ignore the attempt.
The trigger ready signal will only be available when hardware triggering is
enabled.
Image Acquisition N
Exposure
Readout
Time
Signal goes high
at earliest safe
moment to trigger
acquisition N+1
TrigRdy
Signal
Signal goes low
when exposure
for acquisition
N+1 begins
Image Acquisition N+1
Exposure
Readout
Image Acquisition N+2
Exposure
Readout
Signal goes high
at earliest safe
moment to trigger
acquisition N+2
Signal goes low
when exposure
for acquisition
N+2 begins
Summary of Contents for scout GigE
Page 4: ......
Page 50: ...Specifications Requirements and Precautions AW00011916000 40 Basler scout GigE...
Page 52: ...Installation AW00011916000 42 Basler scout GigE...
Page 66: ...Basler Network Drivers and Parameters AW00011916000 56 Basler scout GigE...
Page 80: ...Network Related Camera Parameters and Managing Bandwidth AW00011916000 70 Basler scout GigE...
Page 184: ...Image Acquisition Control AW00011916000 174 Basler scout GigE...
Page 206: ...Color Creation and Enhancement AW00011916000 196 Basler scout GigE...
Page 232: ...Pixel Data Formats AW00011916000 222 Basler scout GigE...
Page 354: ...Chunk Features AW00011916000 344 Basler scout GigE...
Page 358: ...Troubleshooting and Support AW00011916000 348 Basler scout GigE...
Page 367: ...AW00011916000 Revision History Basler scout GigE 357...
Page 368: ...Revision History AW00011916000 358 Basler scout GigE...