Image Acquisition Control
Basler scout GigE
107
process of exposing and reading out a frame (see Figure 46 on
page 107
). As soon as the camera
is ready to accept another frame start trigger signal, it will return to the "waiting for frame start
trigger" acquisition status. A new frame start trigger signal can then be applied to the camera to
begin another frame exposure.
The frame start trigger has two modes: off and on.
If the Trigger Mode parameter for the frame start trigger is set to off, the camera will generate all
required frame start trigger signals internally, and you do not need to apply frame start trigger
signals to the camera. The rate at which the camera will generate the signals and acquire frames
will be determined by the way that you set several frame rate related parameters.
If the Trigger Mode parameter for the frame start trigger is set to on, you must trigger frame start by
applying frame start trigger signals to the camera. Each time a trigger signal is applied, the camera
will begin a frame exposure. When frame start is being triggered in this manner, it is important that
you do not attempt to trigger frames at a rate that is greater than the maximum allowed. (There is
a detailed explanation about the maximum allowed frame rate at the end of this chapter.) Frame
start trigger signals applied to the camera when it is not in a "waiting for frame start trigger"
acquisition status will be ignored.
= a frame start trigger signal that will be ignored because the camera
is not in a "waiting for frame start trigger" status
= camera is waiting for an acquisition start trigger signal
= camera is waiting for a frame start trigger signal
= frame exposure and readout
Acquisition Frame Count parameter setting = 3
= frame transmission
Fig. 46: Acquisition Start and Frame Start Triggering
Frame Start
Trigger Signal
Acquisition Start
Trigger Signal
Time
Acquisition
Start
Command
Executed
Acquisition
Stop
Command
Executed
Summary of Contents for scout GigE
Page 4: ......
Page 50: ...Specifications Requirements and Precautions AW00011916000 40 Basler scout GigE...
Page 52: ...Installation AW00011916000 42 Basler scout GigE...
Page 66: ...Basler Network Drivers and Parameters AW00011916000 56 Basler scout GigE...
Page 80: ...Network Related Camera Parameters and Managing Bandwidth AW00011916000 70 Basler scout GigE...
Page 184: ...Image Acquisition Control AW00011916000 174 Basler scout GigE...
Page 206: ...Color Creation and Enhancement AW00011916000 196 Basler scout GigE...
Page 232: ...Pixel Data Formats AW00011916000 222 Basler scout GigE...
Page 354: ...Chunk Features AW00011916000 344 Basler scout GigE...
Page 358: ...Troubleshooting and Support AW00011916000 348 Basler scout GigE...
Page 367: ...AW00011916000 Revision History Basler scout GigE 357...
Page 368: ...Revision History AW00011916000 358 Basler scout GigE...