AW00011916000
Physical Interface
Basler scout GigE
85
Voltage Levels When a PLC Power and I/O Cable is Used
The following voltage requirements apply to the input of the PLC power and I/O cable. The PLC
power and I/O cable will adjust the voltages to the levels required at the camera’s I/O input (see
Table 7).
Voltage
Significance
+0 to +24 VDC
Recommended operating voltage.
+0 to +8.4 VDC
The voltage indicates a logical 0.
> +8.4 to +10.4 VDC
Region where the transition threshold occurs; the logical state is not defined in this
region.
> +10.4 VDC
The voltage indicates a logical 1.
Table 10: Voltage Requirements for the I/O Input When Using a PLC Power and I/O Cable