Configuring the Camera
BASLER A102
k
4-17
DRAFT
4.2.4.10 Gain
4.2.4.11 Offset
Purpose:
To set the gain or to read the current gain setting. See Section
for more information on
gain.
Type:
This is a read or write command.
Read Command:
Cmd-ID
R/W-Flag
Data Length
Data
0x80
1
2
-
Response:
Cmd-ID
R/W-Flag
Data Length
Data
0x80
0
2
2 Bytes
Write Command:
Cmd-ID
R/W-Flag
Data Length
Data
0x80
0
2
2 Bytes
Response:
None
Data Format:
Byte 1
Low byte of gain setting
Byte 2
High byte of gain setting
Data Range:
Gain settings can range from 0 (0x0000) to 1023 (0x03FF). The minimum
recommended setting is 184 (0x00B8) with vertical binning disabled or 144
(0x0090) with vertical binning enabled. See Section
.
Purpose:
To set the offset or to read the current offset setting. See Section
for more information
on offset.
Type:
This is a read or write command.
Read Command:
Cmd-ID
R/W-Flag
Data Length
Data
0x84
1
2
-
Response:
Cmd-ID
R/W-Flag
Data Length
Data
0x84
0
2
2 Bytes
Write Command:
Cmd-ID
R/W-Flag
Data Length
Data
0x84
0
2
2 Bytes
Response:
None
Data Format:
Byte 1
Low byte of offset setting
Byte 2
High byte of offset setting
Data Range:
Offset settings can range from 0 (0x0000) to 255 (0x00FF).
Summary of Contents for A102K
Page 4: ......
Page 16: ...Introduction 1 8 BASLER A102k DRAFT...
Page 36: ...Camera Interface 2 20 BASLER A102k DRAFT...
Page 38: ...Operation and Features 3 2 BASLER A102k DRAFT Figure 3 1 A102k Sensor Architecture...
Page 112: ...Configuring the Camera 4 34 BASLER A102k DRAFT...
Page 118: ...Mechanical Considerations 5 6 BASLER A102k DRAFT...
Page 130: ...Feedback iv BASLER A102k DRAFT...