Troubleshooting
BASLER A102
k
6-3
DRAFT
Check the setup on your frame
grabber and make sure that the
ExSync signal is not too short. The
period of the ExSync signal must
be greater than 67.5 ms.
(On many frame grabbers, the
period of the ExSync signal is
adjusted by changing a setting for
the “frame rate”. Your frame rate
should not exceed 14.8 fps.)
Is the ExSync period OK?
Yes
No
Correct
the
settings.
Check your exposure setting.
The exposure time must be
less than the ExSync period.
Is the exposure OK?
Switch on test image one.
Can the test image be seen?
Correct
the
setting.
Go to the
interfacing
troubleshooting
chart.
Replace the camera.
No
No
Yes
Are you controlling the camera
with an ExSync signal or is the
camera in free-run?
ExSync signal.
Free-run.
CCT+
Check to make sure that:
Timer 1 is set no lower than
15 µs.
Timer 2 is set no lower than
70 µs.
The sum of the Timer 1 setting
plus the Timer 2 setting is
greater than 67.5 ms.
Are the settings OK?
No
Correct
the
settings.
Binary
Commands
Did you set up free-run using the Exposure Time Control Mode
setting on the CCT+ or with binary commands?
Yes
Yes
Switch on the test image one.
Can the test image be seen?
Go to the
interfacing
troubleshooting
chart.
Replace the camera.
No
Yes
Summary of Contents for A102K
Page 4: ......
Page 16: ...Introduction 1 8 BASLER A102k DRAFT...
Page 36: ...Camera Interface 2 20 BASLER A102k DRAFT...
Page 38: ...Operation and Features 3 2 BASLER A102k DRAFT Figure 3 1 A102k Sensor Architecture...
Page 112: ...Configuring the Camera 4 34 BASLER A102k DRAFT...
Page 118: ...Mechanical Considerations 5 6 BASLER A102k DRAFT...
Page 130: ...Feedback iv BASLER A102k DRAFT...