Mechanical Considerations
5-4
BASLER A102
k
DRAFT
5.4
Positioning Accuracy of the Sensor Chip
Positioning accuracy of the sensor chip in the horizontal and vertical direction is ± 0.15 mm.
Rotational positioning accuracy is as shown in Figure 5-4. Reference position is the center of the
camera housing.
Since the translatory and rotational positioning tolerance depend on each other, the worse case
of maximum rotational and horizontal/vertical mis-positioning can not occur at the same time.
Figure 5-4: Rotational Positioning Accuracy
Drawings are not to scale.