PARAMETER
RANGE
OF
VALUES
DEFAULT
VALUE
FUNCTION
Frame
9
ON/OFF
OFF
Automatically moves the panto-
graph forward at the end of the
pattern, by the height of the pat-
tern, unless a new value is pro-
grammed in F. Offset parameter.
10
F. Offset
-999mm to
300mm
Ømm
Sets the amount the pantograph
will move when Frame is on. If set
at Ø, the pantograph moves for-
ward by the height of the pattern.
11
Repeat
1 - 201
1
Sets the number of times a pattern
will be repeated. Set at 201, the
pattern will sew an infinite number
of repeats.
12
CAP Frame
Ø - 2
Ø
Sets the machine up for a cap
frame, enabling use of the raised
throat plate, or spectacle frame,
allowing you to merge patterns
executing pantograph movement
exactly as programmed.
Ø = Off
1 = Cap Frame
2 = Spectacle Frame
13
Frame Type
0-3
0
Able to set frame preference for
the use of sub soft limits. 0 - off,
Frame 1, 2, 3 programmable.
Changing Program Parameters
1.
Press the Memory softkey. The pattern list displays, showing the
patterns stored in memory.
2.
Use the jog keys to select a pattern from the list. A box outline displays
around the selected pattern.
3.
Press C, below the Program icon. The list of program options displays.
BENS Operation Guide - 12/99
Memory Operations 2-17
Memory
Softkey
Summary of Contents for BENS
Page 1: ......
Page 6: ...Chapter 1 Overview BENS Operation Guide 12 99 Overview 1 1...
Page 21: ...Menu Overview 1 16 Overview BENS Operation Guide 12 99...
Page 32: ...Chapter 2 Memory Operations BENS Operation Guide 12 99 Memory Operations 2 1...
Page 64: ...Chapter 3 Sewing BENS Operation Guide 12 99 Sewing 3 1...
Page 91: ...Chapter 4 Error Codes BENS Operation Guide 12 99 Error Codes 4 1...